Rondo’s recent findings show why coating mass, product identification and on-site verification matter long after the plasterboard goes up.

For commercial builders, contractors, specifiers and certifiers, concealed steel framing is not a place where apparent equivalence should be accepted without verification. Once walls and ceilings are lined, the product may disappear from view, but the consequences of inadequate corrosion protection can remain embedded in the building.
What Rondo found
After a certifier requested sections of internal wall and ceiling linings be removed, rust was visible on imported steel framing. Samples of the corroded furring channel and steel stud were then independently tested for zinc coating mass.

Rondo states that its furring channel and steel stud use a Z275 coating, equivalent to a coating mass of 275 g/m². In Rondo’s comparison, the tested furring channel had less than one-tenth of that coating mass, while the tested steel stud had a little more than one-third. Rondo also notes that the 23 g/m² result was below the informative recommendation of minimum Z180 for internal ceilings in AS/NZS 2785.
Why zinc coating mass matters
Zinc coating protects steel from corrosion. Rondo’s communication explains that a lower coating mass provides less protection against moisture and environmental conditions, including in internal wall and ceiling applications. Its materials engineers estimated that red rust could appear within six months of exposure for the tested furring channel in a relatively mild C3 corrosion zone.
The laboratory results were consistent with earlier testing
Rondo’s Cutting Corners investigation compared imported steel products with Rondo samples under accelerated salt spray testing. Rondo reported red rust on imported samples within 200 hours and significant corrosion by 400 hours, while its own samples showed no visible red rust over the same period. The building inspection adds a real-world example to those controlled test results.
The commercial impact goes beyond replacing the steel
Where concealed framing has corroded, rectification can require walls and ceilings to be opened, framing to be removed and replaced, and areas to be relined, replastered and repainted. Rondo identifies the resulting exposure as a combination of time, labour, materials, disruption and potential reputational consequences.
Before linings are installed, verify the product
|
PROJECT ROLE |
PRACTICAL CHECK |
|
Specifiers |
Require clear Rondo product identification so the specified framing can be confirmed. |
|
Builders |
Check delivered materials and verify branding before walls and ceilings are lined. |
|
Installers |
Confirm the Rondo name before installation and again before the framing is concealed. |
|
Certifiers |
Use visible product identification to support verification before linings are installed. |
Specify Rondo. Verify Rondo.
Rondo metal products are inkjet printed, while its clips are stamped with the Rondo brand. This visible identification allows project teams to check that genuine Rondo products have been supplied and installed before they are concealed behind plasterboard. Similar dimensions or appearance alone do not confirm equivalent coating mass, durability or performance.
The lowest upfront material price can become the most expensive choice once investigation, removal, replacement and reinstatement are considered. For your next wall or ceiling package, specify genuine Rondo framing and make product verification part of the pre-lining inspection. Contact your NHS representative for Rondo product supply and project support.
Source and attribution
This customer communication is an NHS summary of findings published by Rondo Building Services in “The Real Cost of Cutting Corners: Corrosion Discovered in a Building Less Than Five Years Old”, dated 7 September 2026. Technical results and project observations are attributed to Rondo’s published communication.